Using FTP to Upload the Firmware and Configuration Files
In addition to upload the firmware and configuration file via the console port and TFTP client, you can also upload the firmware and configuration files to the P-334U/P-335U using FTP.
To use this feature, your workstation must have a FTP client software. There are two examples as shown below.
Step 1 |
Use FTP client from your workstation to connect to the P-334U/P-335U by entering the IP address of the P-334U/P-335U. |
Step 2 |
Press 'Enter' key to ignore the username, because the P-334U/P-335U does not check the username. |
Step 3 |
Enter the console mode password as the FTP login password, the default is '1234'. |
Step 4 |
Enter command 'bin' to set the transfer type to binary. |
Step 5 |
Use 'put' command to transfer the file to the P-334U/P-335U. |
Note: The remote file name for the firmware is 'ras' and for the configuration file is 'rom-0' (rom-zero, not capital o).
Example:
C:\temp>ftp
202.132.155.97 |
Here, the 'p312.bin' is the local file and 'ras' is the remote file that will be saved in the P-334U/P-335U.
The P-334U/P-335U reboots automatically after the uploading is finished.
Step 1 |
Rename the local firmware and configuration files to 'ras' and 'rom-0', because we can not specify the remote file name in the FTP client software. |
Step 2 |
Use FTP client from your workstation to connect to the P-334U/P-335U by entering the IP address of the P-334U/P-335U. |
Step 3 |
Enter the console mode password as the FTP login password. The default is '1234'. |
Step 4 |
Press 'OK' key to ignore the username, because the P-334U/P-335U does not check the username. |
Example:
1. Connect to the P-334U/P-335U by entering the P-334U/P-335U's
IP and console mode password in the FTP software. Set the transfer type to 'Auto-Detect'
or 'Binary'.
2. Press 'OK' to ignore the 'Username'
prompt.
3. To upload the firmware file, we transfer the local 'ras' file to overwrite the remote 'ras' file.
To upload the configuration file, we transfer the local 'rom-0'
to overwrite the remote 'rom-0' file.
4.The P-334U/P-335U reboots automatically after the uploading is finished.
All contents copyright (c) 2006 ZyXEL Communications Corporation.